[Case Study] Achieving Stable Operation of Dust Collectors by Reviewing Sensors
Stable operation of dust collectors by reducing false detection risks! A case of preventing false detection during vehicle passage.
In the process of collecting foundry waste materials, there was a challenge of wanting to control the operation of the dust collector through vehicle detection. Therefore, we controlled the dust collector using an underground embedded loop coil for vehicle detection. This prevents false detection when vehicles pass by and avoids the risk of physical damage to the sensors. As a result, by utilizing the loop coils used in the Amano parking system, we achieved improved maintainability and smooth parts supply. 【Issues】 ■ We want to detect the position of forklifts to change the dust collection location and open and close doors. ■ The use of sensors such as photoelectric tubes and infrared sensors poses a risk of damage due to contact when forklifts pass. ■ The site has a lot of dust, leading to frequent false detections caused by dirt adhering to the sensors. *For more details, please refer to the PDF document or feel free to contact us.
- Company:アマノ
- Price:Other